YSSY-110 Medical Portable Blood And Fluid Infusion Warmer
| Item |
Specification |
| Temperature Setting |
℃:35℃-42℃ |
| °F:95.0°F-107.6°F |
| Temperature Accuracy |
℃:±1℃ |
| °F:±1.8°F |
| Increment |
℃:0.1℃ |
| °F:0.2°F |
| Optional unit |
℃/°F |
| Warming Up time |
≤2min |
| Overheat Protection |
46℃ |
| Alarm |
Overheat, low temperature, system error, door open, warming up alarm. |
| Display |
LED |
| Power Supply |
Input:100-240V(AC Power),50/60HZ,0.3-0.7A Output:12V(DC Power) 2.5A |
| Power Consumption |
85VA |
| Operation Environment |
Temp.:+5℃-+30℃ |
| Relative Humidity:20%-80% |
| Atmosphere:76.0kPa-106.0kPa |
| Transportation and Storage Environment |
Temp.:-20℃-+55℃ |
| Relative Humidity:10%-93% |
| Atmosphere:50.0kPa-106.0kPa |

Technical Specification:
Infusion rate range
Adjustable drop rate range: 1 /min~400 drops/min
(step: 1 drop /min)
Adjustable flow rate range: 1ml/h~1200ml/h
(step 0.1ml/h)
Purge rate: 800ml/h
KVO rate: 1ml/h (less than 100ml/h)
2ml/h (100~300ml/h)
3ml/h (greater than 300ml/h)
Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
Infusion Time range: 1min~9999min (step: 1 min)
Infusion accuracy: Within ±3% (using calibrated high quality IV set)
Mechanical precision: within ±2%
Occlusion alarm threshold:
High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Size: 515mm(L)×145mm(W), allowed deviation: ±5%
SpO2 sensor
Type: Finger clip type
Wire length: 3000mm, allowed deviation: ±5%
Human body contact materials: Silicone
Size: 188 mm(L)×198 mm(W)×228 mm(H)
Net weight: 2.5kg
Technical Specification:
Infusion rate range
Adjustable drop rate range: 1 /min~400 drops/min
(step: 1 drop /min)
Adjustable flow rate range: 1ml/h~1200ml/h
(step 0.1ml/h)
Purge rate: 800ml/h
KVO rate: 1ml/h (less than 100ml/h)
2ml/h (100~300ml/h)
3ml/h (greater than 300ml/h)
Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
Infusion Time range: 1min~9999min (step: 1 min)
Infusion accuracy: Within ±3% (using calibrated high quality IV set)
Mechanical precision: within ±2%
Occlusion alarm threshold:
High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Size: 515mm(L)×145mm(W), allowed deviation: ±5%
SpO2 sensor
Type: Finger clip type
Wire length: 3000mm, allowed deviation: ±5%
Human body contact materials: Silicone
Size: 188 mm(L)×198 mm(W)×228 mm(H)
Net weight: 2.5kg